Batch report — full panel

RT-40-V-001

The Reta 40mg vial batch, and the most completely tested record in this library. Janoshik Analytical returned 99.692% HPLC purity alongside TAMC/TYMC microbial-limit, bacterial-endotoxin, heavy-metals and residual-TFA results — five separate reports, five separately confirmable verification keys.

For in-vitro laboratory research only. Not for human or veterinary use.

Batch facts

Format
Reta 40mg Vial (lyophilised)
Batch number
RT-40-V-001
Molecule
Reta (LY-3437943) — CAS 2381089-83-2
Purity (HPLC)
99.692%
Assay
49.80 mg retatrutide
Microbial limits — TAMC
Pass
Microbial limits — TYMC
Pass
Bacterial endotoxin (LAL)
<1 EU/Vial
Heavy metals (As, Cd, Pb, Hg)
Not detected
Residual TFA
Not detected
Laboratory
Janoshik Analytical
Sample received
27 May 2026
Analysis dates
1–16 June 2026
Dataset 2.0.1 record: modified 1 August 2026. Published tests: HPLC purity and assay, microbial enumeration (TAMC/TYMC), bacterial endotoxin, heavy metals and residual TFA. Mass-spectrometric identity is not published for this batch. Open the downloadable record and release history.

Verify each report yourself

Janoshik issues one report — and one verification key — per test. Copy any key below and enter it at janoshik.com to pull the original report straight off the laboratory's own server. No key, no proof: a batch number that returns nothing is an unverified claim.

RT-40-V-001 — Janoshik verification keys
Test Result Verification key
HPLC purity 99.692%
Microbial limits (TAMC/TYMC) Pass
Bacterial endotoxin (LAL) <1 EU/Vial
Heavy metals Not detected
Residual TFA Not detected

For the verification method behind this record, read how to verify a Janoshik COA and how to interpret peptide COA and HPLC purity evidence.

Exact format relationship: this batch documents the Reta 40mg Vial. The batch record and its five-report analytical panel are published here; the reusable machine-readable version lives in the public COA evidence dataset.

The five Janoshik reports

Each image below is the original Janoshik report, mirrored locally. The full panel is also available as a single PDF.

HPLC purity — 99.692%

Chromatographic purity and quantitative assay (49.80 mg). Janoshik task 165576 · verification key 891L96KSY7Z8.

Janoshik HPLC purity report for batch RT-40-V-001 — 99.692% HPLC Reta 40mg vial

Microbial limits — TAMC and TYMC pass

Microbial enumeration for total aerobic microbial count and total yeast/mould count. Janoshik task 165579 · verification key 7HDEPPG16HDB.

Janoshik TAMC and TYMC microbial-enumeration report for batch RT-40-V-001

Bacterial endotoxin — <1 EU/Vial

LAL assay. Endotoxin is measured separately from microbial enumeration because it can be present where no viable organism grows. Janoshik task 165578 · verification key UYLI4AFJK4SV.

Janoshik bacterial endotoxin LAL report for batch RT-40-V-001 — under 1 EU per vial

Heavy metals — not detected

Arsenic, cadmium, lead and mercury. Janoshik task 165580 · verification key ENHRQB3GVEXF.

Janoshik heavy metals report for batch RT-40-V-001 — arsenic, cadmium, lead and mercury not detected

Residual TFA — not detected

Trifluoroacetic acid is a common residual counter-ion from peptide synthesis. Janoshik task 165577 · verification key 8KB3WYGVT9VZ.

Janoshik residual TFA report for batch RT-40-V-001 — not detected

Common questions

What is batch RT-40-V-001?
The Reta 40mg vial batch. Janoshik Analytical analysed it between 1 and 16 June 2026 at 99.692% HPLC purity, with a 49.80 mg assay result plus TAMC/TYMC microbial-limit, endotoxin, heavy-metals and residual-TFA results.
Why does RT-40-V-001 carry five verification keys?
Janoshik issues a separate report, and therefore a separate verification key, for each test performed. This batch was tested for HPLC purity, TAMC/TYMC microbial limits, bacterial endotoxin, heavy metals and residual TFA — so five keys can be confirmed independently at janoshik.com.
Does a TAMC/TYMC pass mean the same thing as endotoxin testing?
No. TAMC/TYMC are microbial-enumeration results. The LAL assay measures bacterial endotoxin, which can be present even where no viable organism grows. Neither result alone establishes compendial sterility; each test has its own Janoshik report and verification key.
Which format is associated with batch RT-40-V-001?
The Reta 40mg vial format. The batch record for that format and its five-report analytical panel are published on this page, with every task number and verification key confirmable through Janoshik directly.

Continue through the evidence trail

This is the most completely tested batch in the library. Compare it against the other published records, or read how the purity, microbial and endotoxin numbers on a COA relate to one another.