October 20, 2026: Initial publication.
Record scope

RET-20-V-2604-001 describes a submitted 20mg retatrutide sample. The published batch record calls it lyophilised and maps the record to the supplier’s 10mg and 40mg pens. That mapping does not make a finished pen or a later shipping lot the tested sample.

RET-20-V-2604-001 quick record

Sample scope: The published batch record describes a Retatrutide 20mg lyophilised sample. The Janoshik image names “Retatrutide 20mg.” Supplier mapping points to its 10mg and 40mg pens.

Six tests listed for this sample, with their reported results and limits
Test and taskReported findingRead it as
HPLC purity + quantitative assay
Task 112563
99.741% purity; 20.92mg assaySeparate HPLC result fields. Purity is not amount by weight.
Mass (CHNS)
Task 112566
Retatrutide (CHNS), 21.80mgA CHNS (elemental analysis) mass result, separate from the HPLC assay.
LCMS contamination screen
Task 112567
“No significant contamination detected.” The report also notes mannitol, disaccharide, retatrutide and degradation products.A screen result, not a sterility or all-contaminants finding.
Heavy metals
Task 112569
Arsenic, cadmium, lead and mercury not detectedThese four named metals only.
Residual TFA
Task 112564
Not detectedThe TFA result only.
Bacterial endotoxin (LAL)
Task 112565
1.449 EU/vialAn endotoxin result. No sterility test is listed.

Report notes

Batch on report:   Sample named:

Format received:   Task / method:

Result and units:   Limit or open question:

Source: published batch record · Task 112563 report PDF.

For in-vitro laboratory research only. Not for human or veterinary use.

Read the sample line before the percentage

The Janoshik report image lists task 112563, sample “Retatrutide 20mg,” batch RET-20-V-2604-001, and ProPeptide in the manufacturer field. The published batch record describes the sample format as “Reta 20mg (lyophilised sample).” The supplier mapping names ProPeptide Retatrutide Pen 10mg and Pen 40mg, with the relationship marked “supplier-mapped.”

Use that mapping to understand which supplier formats the record references. The batch page and COA library hold the published record.

Task 112563: purity and assay

Janoshik task 112563 report. Sample Retatrutide 20mg, batch RET-20-V-2604-001; result 20.92mg retatrutide and 99.741% purity.
Original Janoshik report image for task 112563. The image names the 20mg sample and batch, gives the 20.92mg assay and 99.741% purity, and prints verification key YCYA75M373NA.

The report records “Common GLP-1 peptide blind test (Semaglutide, Tirzepatide and Retatrutide)” as the requested test. The published batch record labels the task “HPLC purity and quantitative assay.” It records 99.741% purity and a separate 20.92mg assay result. Read those as separate fields.

The report comment says the peak with lambda maximum 201, 209 and 229nm was not counted among impurities. Keep that note with the reported purity. No task is named “identity.” Two results bear on it: task 112563 was requested as a blind test for semaglutide, tirzepatide and retatrutide and reported retatrutide, and the LCMS screen lists retatrutide among the substances it detected. Neither is a full sequence confirmation.

Verify Janoshik task 112563 using the task number and printed key. See the Janoshik COA verification guide for the lookup steps and the COA and HPLC guide for the broader terms.

The other five task records

Each entry is one recorded task. The mass result does not replace the HPLC assay. The LCMS result keeps its stated qualifier, “no significant contamination detected,” alongside the substances named in the comment. The heavy-metal and TFA results refer to their named tests.

What the six entries leave open

The published batch record lists no sterility test, no test of a finished 10mg or 40mg pen and no test of a later shipping lot.

The listed metals are arsenic, cadmium, lead and mercury. The residual result is for TFA. The LCMS task is a contamination screen with the stated result and comment. These records do not establish the absence of every possible contaminant, or suitability for human or veterinary use.

For broader interpretation of purity, assay and report fields, use the peptide COA and HPLC purity guide. For source and key checks, use How to verify a Janoshik COA.

Our Research Standards

Every figure on this page matches the published batch record for RET-20-V-2604-001, the Janoshik report image for task 112563 and the six Janoshik verification links, as checked on October 20, 2026.

RP
Editorial Review

Editorial Board, Remy Research

The Remy Research Editorial Board reviews Remy's peptide research library, with a focus on analytical verification, clinical-trial interpretation, and compliance-safe scientific communication.

About the editorial team →

Frequently Asked Questions

What sample does report RET-20-V-2604-001 describe?
The Janoshik report for task 112563 names “Retatrutide 20mg” as the sample. The published batch record describes RET-20-V-2604-001 as a 20mg lyophilised sample and maps the record to the supplier’s 10mg and 40mg pens. The report does not establish that either filled pen or a later shipping lot was tested.
Does 99.741% HPLC purity mean the sample contained 99.741% peptide by weight?
No. In task 112563 the published batch record records 99.741% HPLC purity and a separate 20.92mg quantitative assay result. The percentage and assay are separate result fields.
Does the endotoxin result show sterility?
No. Task 112565 is a bacterial endotoxin result by LAL at 1.449 EU per vial. The published batch record lists no sterility test for this record.
Which tests are listed for this sample?
Six tasks appear in the published batch record: HPLC purity and quantitative assay, Mass (CHNS), LCMS screening for peptide contamination, heavy metals, residual TFA, and bacterial endotoxin (LAL).
Which claims are outside this record?
The record does not show a test of a finished 10mg or 40mg pen, a later shipping lot, sterility, or human or veterinary safety.

Sources and verification

  1. Remy Research COA batch dataset, record RET-20-V-2604-001. Read-only source for the sample description, supplier mapping, six test names, dates, results and report URLs.
  2. Published batch page for RET-20-V-2604-001.
  3. Original Janoshik task 112563 report image and PDF; Janoshik verification record.
  4. Janoshik verification records for task 112566, task 112567, task 112569, task 112564 and task 112565.